Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. bras. oftalmol ; 79(2): 95-98, Mar.-Apr. 2020. tab, graf
Article in Portuguese | LILACS | ID: biblio-1137937

ABSTRACT

Resumo Objetivo: Avaliar o astigmatismo induzido pela cirurgia de catarata através da técnica de facoemulsificação (FACO) guiada pelo planejador cirúrgico VERION®, em um serviço oftalmológico do Paraná. Métodos: O estudo tem caráter observacional com avaliação individualizada de prontuários de forma retrospectiva, analisando 37 olhos de 20 pacientes operados de catarata pela técnica de FACO com a utilização do VERION® e implantação de lente não-tórica no Hospital de Olhos de Cascavel - PR no período de maio de 2016 a novembro de 2018. Resultados: Dentro de nossa amostra composta por 37 olhos abordados com assistência do VERION®, 43% dos participantes do estudo (n=16) apresentaram redução do astigmatismo inicial, inclusive com eliminação de graus mais graves de astigmatismo (≥2.5 D). Conclusão: O impacto do VERION® foi significativo uma vez que permitiu a correção do astigmatismo prévio de uma parte da amostragem. Em olhos que ocorreram astigmatismo induzido cirurgicamente essa complicação foi menos relevante clinicamente em comparação com incisões corneanas da técnica convencional.


Abstract Objective: To evaluate the astigmatism induced by cataract surgery through the phacoemulsification (PHACO) technique guided by the VERION® surgical planner, in an ophthalmological service of Paraná. Methods: This is an observational study with retrospective individualized evaluation of medical records, analyzing 37 eyes of 20 patients who underwent cataract surgery using the PHACO technique using VERION® and non-toric intraocular lens implantation at the Hospital de Olhos de Cascavel - PR in May 2016. Results: Within our sample of 37 eyes approached with VERION® assistance, 43% of study participants (n=16) had reduced initial astigmatism, including elimination of more severe degrees of astigmatism (≥2.5 D). Conclusion: The impact of VERION® was significant as it allowed the correction of previous astigmatism of a part of the sample. In eyes that had surgically induced astigmatism, this complication was less clinically relevant compared to conventional technique corneal incisions.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Astigmatism/complications , Astigmatism/epidemiology , Cataract Extraction/adverse effects , Phacoemulsification/methods , Surgery, Computer-Assisted , Retrospective Studies , Corneal Topography/methods , Observational Study
SELECTION OF CITATIONS
SEARCH DETAIL